No Products in the Cart
Design your own 00 B&S cable with the choice of:
and we will custom build it for you. (Each selection includes assembly fees)
Scroll for cable specifications...
AMP Rating at 30°C: 292 amp (JASO D609 derating factors apply)
Tycab Code: ABC191003
Nearest AWG: 00
Strand #/Size: 798/0.32
Nominal Area: 64.15mm²
Insulation Thickness: 1.7mm
Electrical Resistance at 20°C: 0.3 ohm/km
Nominal O.D.: 14.5mm
Mass (kg/100m): 70.1
Conductor: OXYGEN FREE Plain Copper Wire to AS/NZS 1125
Insulation: V90 degrees Celsius PVC to AS/NZS 3808
Download Sizing Guide:
Voltage Drop for 0 B&S Cable:
To calculate the voltage drop of 0 B&S copper cable, use the following formula:
Voltage Drop = Length x Current x 0.017
Length = Total length of cable in metres.
Current = Current draw (amps) through the cable.
Area = Cross sectional area of the copper (in this case 49.00mm²)
Notes:
Formula only applies to copper at 25°C, voltage drop increases with both ambient and cable temperature, at approx 0.4% per °C.
0.017 - This multiplication factor only applies to copper
Example for 0 B&S:
How much voltage drop over 10m of 0 B&S with a current draw of 246A?
Divide this by 49.00 (cross sectional area of 0 B&S - mm²)
You will have a drop of approximatley 0.85 Volts over the 10m length